        Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
         
         
         
         
         
        Glass Tube Flowmeter
        LZB/LZJ series glass rot...
        Glass Tube Flowmeter
        Glass Tube Flowmeter
        LZB-()W/WB series micro ...
        Glass Tube Flowmeter

         


        CF2002 Integrated Digital ? Intelligent Transmitter

        General View

         CF 2002 integrated absolute pressure / pressure transmitter
        adopts diffused silicon isolation type sensor modules that
        are of high precision and high stability, converting the
        absolute pressure of the tested medium or gauge pressure
        into standard 4 ~ 20 mA DC electric signal through highly
        reliable amplifying circuit and precision temperature
        compensation. Elaborate packaging techniques and perfect
        assembling technology ensure excellent product quality and
        the most optimal performance of the product. The product
        is featured with complete types and specifications,
        normalized interface form, convenient adjustment of zero
        point and range adjustment etc, with which customer
        demands can be fulfilled to the most.
        CF 2002 integrated transmitter series can be widely used
        in various tough and dangerous industrial environment.

         

         

        *Features

        Range: 0 ~ 5KPa to 0 ~ 32 MPa (referring
        to type selection table)
        Over load pressure: 2 times of max range
        state or 70 MPa (the min. value)
        Output signal: 4 ~ 20 mA DC (two wire
        system)
        Operation voltage: 14 ~ 36 V DC (two wire
        system) standard 24V DC ±5%, ripple less
        than 1%.
        Temperature of the medium: - 25℃ ~ + 100℃
        Ambient temperature: -
        Relative humidity: 0% ~ 100%

         

        Load resistance:
        (4 ~ 20 mA) : R = [(U – 14) / 0.02] – R0
        In which U is power supply voltage; R0 is the
        internal resistance of the cable.
        (0 ~ 10 mA) : R ¡Ü1 Kohm
        (0 ~ 5 V) : R ¡Ý300 ohm

         Min. measuring range over 5 KPa.
        Max measuring range 0 ~ 32 MPa
        Direct process connection, no braket
        installation needed.
        Zero point and range continuously
        adjustable externally.
        Lightning proof, RF interference proof
        With local indication
        Intrinsic safety explosion proof or flame
        proof
        Small volume, good-looking appearance,
        high cost efficiency.
        High precision, high stability, and high

         reliability.
        *Applications
        Liquid level measuring and controlling on
        industrial sites
        Pressure testing system in laboratories
        Ocean navigation and ship building
        Aviation and aircraft manufacturing
        Air separation plant and heat power units
        Energy source management system
        Liquid level measuring and water supply
        system
        Hydraulic pneumatic control system
        *Technical indexes
        Mediums to be measured: Various liquids,
        gases or steams compatible with 316L
        stainless steel

         

        Performance indexes

        Accuracy:
        ± 0.1% (including the comprehensive error of nonlinearity, repeatability and return error).
        Zero point deviation:
        Positive deviation: 0% ~ + 80% of max range state; negative deviation: 0% ~ -100% of max
        range state (not exceeding -100 KPa, absolute pressure products have no negative deviation).
        Range adjustment:
        Adjustable freely between the min. range and max range state (see type selection table).
        Influence of over pressure:
        Less than 0.25% of max range state.
        Influence of power supply
        Less than 0.01% V of output range.
        Load influence:
        Negligible.
        Influence of temperature:
        ±1.5% of max range state (temperature range: - 20% ~ + 85%, including total temperature
        influence of zero point and the range).
        Stability:
        ±0.25% / year of max range state.
        Ø Features of structure:
        Material of diaphragm: 316L stainless steel
        Connection material: 1 Cr 18Ni 9Ti stainless steel
        Casing material: 1 Cr 18Ni 9Ti stainless steel
        Process interface: M20 x 1.5, NPT 1 / 2 or G1 external thread (large opening).
        Electrical interface:
        Standard water proof plug
        Indication meter: none
        Weight: approx. 1.2 kg.
        Explosion proof mark: Ex ia II CT5 (intrinsic safety type); Ex ia II CT5 (flame proof type)
        Overall protection meeting requirements of IP 67 (meeting applicable parameters)



        ? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
        Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
        Friendly Links:成豐儀表阿里巴巴店鋪    新浪    
        主站蜘蛛池模板: 亚洲欧美日韩人成在线播放| 成人性生交大片免费| 2020久久国产综合精品swag| 亚洲国产成人不卡高清麻豆| 丰满人妻一区二区三区四区53| 欧美成妇人吹潮在线播放| 亚洲 欧美 清纯 校园 另类| 久久久久久综合网天天| 综合成人亚洲| 伊人成人在线视频免费| 色综合激情丁香七月色综合| 国产成人露脸自拍视频| 欧美18禁网站国外| 乱码AV麻豆丝袜熟女系列| 人妻av无码系列一区二区三区| 亚洲成人av| A成片人| 中国特黄美女一级视频| 久久精品国产再热青青青| 手机av中文字幕| 亚洲av天天| 国产精品乱码一二三区| 18禁美女裸体爆乳无遮挡| 99riav国产精品视频| jk白丝喷浆| av免费在线观看美女叉开腿| 色综合久久中文综合网| 一区二区三区四区五区自拍| 岛国av无码免费无禁网站| 午夜福利无码一区二区| 亚洲人成网站在线播放2019| 国产亚洲一二三区精品| 偷国产乱人伦偷精品视频| 人妻丝袜美腿中文字幕| 女人天堂av| 91乱子伦国产乱子伦海的味道| 招远市| 国产精品福利午夜一级毛片| 亚洲福利影院| 久久精品一本到99热免费| 国产黄色av网址|